Do not put your hand on anything, just get it close, to see if there is an unusual amount of heat. After you have determined that the sensor is good and that the unit is not overheating, the next step is to replace the thermocouple. The following are five of the top ten reasons a fire won’t start: The thing to keep in mind is that the pilot can go out for a lot of reasons that have nothing to do with the thermocouple. Heat n glo gas fireplaces gas fireplace won t stay lit magic heat glo standing pilot fireplace how to test your thermopile www gas fireplace won t stay lit magic. Unscrew the thermocouple from the gas valve and then set your multimeter to register millivolts. Then you may need to troubleshoot the switch or remote control. Unfortunately, there are times where the fireplace just doesn’t work. Gas Fireplace indoor fireplace pdf manual download. Once you have done this, allow some time for the unit to cool down. Use a flat blade screwdriver to adjust the set screw, on the right side of the gas valve. I'm a writer that is passionate about home improvements, remodeling, and renovating. There is nothing quite like setting the mood and getting things toasty warm by the fire in the dead of winter. Has the pilot light on your Heat & Glo fireplace gone out? Test with a multimeter. Now place the glass assembly back into place. Here is the step by step method to remove the thermocouple. Once the pilot is on, push in the knob again, and set it to the on position. You can do this by putting your hand close to the bottom area, where the switches are. The thing about gas fireplaces is that they rarely offer a flashing sign that says what the problem is. Tour Start here for a quick overview of the site ... Main burner for gas fireplace won't stay lit (pilot light is fine) Ask Question Asked 4 years, 2 months ago. Step 2: Open valve by pivoting handle to be parallel to gas line. Now you will need to loosen the screw that holds the thermocouple in place. After a minute or so, place a lead on the connector and the other lead on the shaft of the thermocouple. Extend the life of the thermopile and your gas fireplace in general by having regular maintenance performed, once a year at least. Check the pilot. If this has happened to... Dryer Smells Like Burning? When the pilot doesn’t light at all, it likely is not the thermocouple that is at fault. What do you suggest? If done properly, the light should start the instant that the flame is close enough to do so. 4. Unfortunately, when the thermopile goes bad, that’s a repair that has to be performed by a professional service. You should hear a beep. Check the main gas valve. Once you have an idea of what might be happening, we have a few ideas to help fix the problem for good. For those uninitiated with gas fireplaces, it may sound confusing to hear that there are electronic components within. Honeywell Thermostat Says The Heat Is On But There Is No Heat? If your Heat & Glo is turning on but then turning off again, then there could be a problem. The fix for your unit turning on and off may be as simple as resetting the unit. If a cold draft blows the pilot out on a regular basis, relight the pilot and check out the vent cap. For this reason, leaving the pilot light on is the best idea. Locate gas supply valve (typically behind louvers, below glass opening - may be red or blue). If this has happened to... Dryer Smells Like Burning? 2. You will need a wrench for this. Gas Fireplace Repair Won T Work Start Or Light Piezo Ignitor. Place the second and remaining wire on the millivolt meter on the solder button on the back of the valve, which is the blue wire. First and foremost, ensure that there aren’t any potential fuel issues keeping your fireplace from lighting. If you have it wired to an on and off switch, then you will need to test the switch. It’s still snowy in Connecticut, offering more opportunities to enjoy your fireplace before warm weather sets in. Joined: Sep 2003 Posts: 11,064 The HEARTland - Ohio: Model BAY-GDV or BAY-GDVDSI Installed 1996 It has piezo ignitor. This is a common problem with Heat & Glo fireplaces. link to Honeywell Thermostat Says The Heat Is On But There Is No Heat? Check the main gas valve to make sure the gas is turned on. After 5 minutes, switch it to the right, back into the remote position. It’s one of those Heat-n-Glo brands, with the glass in front and fake logs and all that. Open valve by pivoting handle to be parallel to gas line. If there is power, but it is not working, then you may need to replace the switch. Ryan also loves hockey and a lifelong Buffalo sports fan. The thermocouple, for instance, will have a probe that is attached to a copper tube. Once you detect a burning smell, you can find... How Do I Turn on My Heat & Glo Fireplace? Not only will it help you find the issue, but it will help you to become more accustomed to your gas fireplace. If the power is fine, check the electronic ignition or possibly replace the fuse. When your dryer produces a burning smell, that is not a good symptom. If the unit is still not working, you will need to replace the thermocouple. Heat & Glo fireplaces can be intimidating to work with at first. A fireplace can be a focal point to any room that it is in. Make sure to hold down the pilot button for 20 seconds or so before releasing it to give the thermocouple the appropriate amount of time to heat up. The pilot light still remains lit. First, hold down the gas control button while also holding the end of your lighter or lit match towards the end of the pilot tube. The valve can get turned off and forgotten about quite easily. Turn the breaker off before doing any work to the switch. link to Dryer Smells Like Burning? Before doing anything, look at the pilot flame. The most common issue is the overheating shutoff sensor, which will cause the unit to shut off, and then back on after it has cooled. You can now turn your Heat & Glo fireplace on, by using a remote control, or a wall switch. 1. This fireplace was here when we purchase the home so I have no manuals. This is located at the back of the gas valve. It makes your home perfectly warm and comfortable. The pilot light systems are actually the most common reason that gas fireplaces do not light, however. There are times, however, that the vent cap will not only be present but completely secure. Heat-n-glo troubleshooting help -- pilot light on but logs won't ignite I have a older AT-SUPREME-C gas fireplace insert form Heat-n-Glo that recently quite working. While holding in the valve knob, start the pilot light on the fireplace. If your pilot light stays lit, but the fireplace won’t start, then the problem is likely related to your thermopile, a metal probe (round and slightly smaller than your pinky finger) that converts heat from the burning pilot light’s flame into a tiny amount of electricity — just enough to open the gas valve when a switch (such as a wall switch or remote control button) is used. This will change the intensity of the flame. How Do You Replace a Thermocouple on a Heat & Glo Fireplace? All of these screws into a designated port on your gas valve. Is your pilot light on, but the unit is not turning on? Another potential issue that can keep your gas fireplace from staying lit is that the thermopile may have gone bad. Place lead connectors. If the switch under the panel is on ON or OFF it still won't come on. Yeah, a real fireplace is nicer, but I’m far too lazy to build fires. Anything less than a 25 millivolt reading and the thermocouple will require replacing. Are you having trouble with your Heat & Glo fireplace turning on and off? Today, I press it, nothing. Dad went on vacation in July. The thermocouple achieves this thanks to the probe. But there is no need for panic. 3. You have your nobs that turn and say Off, On, Pilot. Next, check the unit to make sure it is not overheating. The first thing that you should do is to check the main gas valve. You can do this with a glass cleaner. When I turn it on, it starts up, normal amounts of flame. Clear away the debris and try it again. This was working not even 2 weeks ago, and to my knowledge, nothing has changed other than the temperature outside has dropped about 20 degrees. If it does not light right away, wait a few minutes and then try again. Using a multimeter, you can check this for yourself but may need to have a helper to keep the pilot burning as you do so. Turn the wall switch into on position, and your fireplace will light up. Propane gas fireplaces burn fuel supplied by propane tanks. Help – My Propane Fireplace Won’t Light! Make sure the batteries are working on the remote control. Pilot light is lit. But the thing is that, even though the fuel source is gas, it still uses an electronic ignition to spark the pilot and start the fire in your fireplace. You have to have that set on On. The pilot light comes on but does not spread to the burner. Bypassing the ignition. Checking the thermocouple. This can be caused by several issues. After you have the glass removed, check your igniter by clicking it a few times, to make sure that it’s getting a spark. I've got a video if that would help. Once the pilot is lit, hold the pilot valve in for 60 seconds. Keep your fireplace on a single breaker if at all possible. neighbor’s phone. When the thermocouple is working properly, you will be able to measure between 30 and 40 millivolts of voltage near the connection portion of the tub with the pilot flame on. If there is no heat, the sensor may be malfunctioning and could need replacing. Normally we press a little button to start the fireplace. Place the lead wire, which is marked on the millivolt meter, on the thermocouple copper lead on the Heat & Glo. Worthen adds that spiders and other insects often lay nests inside pilot tubings in … Another issue is that the pilot has gas coming out, but it won’t stay lit. My Pilot Light Will Not Stay Lit Www Mygasfireplacerepair.